Outsourcing Plasma Treatments for Surface Modification

Medical Device Manufacturers Turn to Contract Processors for Plasma Treatments to Enhance the Value of Products

In the medical device industry, plasma treatments are often utilized to solve problems that cannot be resolved other ways.


Whether attempting to improve adhesion of dissimilar materials, depositing coatings, cleaning surfaces, applying a protective coating that repels water for example or biological fluids or enhancing surface wettability or functional coating, plasma treatments often add significant value to medical devices.

For many medical device manufacturers, the application of plasma-applied coatings and surface treatments can play a significant role in new product development, but also when upgrading legacy medical devices under 510(k) guidelines.
As a result, the industry is aggressively investigating and applying plasma to products such as well plates, microfluids, IOL's, stainless-steel guide wires, cardiac pacemaker or implantable cardioverter defibrillators (ICD), catheters, stents, and vascular surgical tools.
"Medical device manufacturers are continuously looking for unique ways to technologically advance their products to be the market leader," says Michael Barden of PVA TePla, a company that designs and manufactures plasma systems, provides surface modification research, and also serves as a contract processing center. "Often, the top tier products incorporate some form of advanced coating to functionalize the surface."

However, when medical device manufacturers want plasma-treated parts or components without having to invest in in-house equipment, the solution is to utilize a contract processor. In this approach, parts are sent in, treated and returned within 1-2 days, or up to a week for larger volumes. For small or infrequent batches, this can lower the price per part significantly.

The most common application for contract processing is to improve the bonding power of chemical adhesives, whether metal to plastic, silicon to glass, polymers to other polymers, biological content to microtiter plates and even bonding to PTFE. However, it also is used often to clean, activate, chemically graft and deposit a wide range of chemistries on the surface of parts or components.

According to Barden, the companies that tend to opt for contract processing generally fall into two categories.

The first has little or no experience with plasma treatments, but may have heard that it can resolve issues or add value to products.

"For many customers, plasma is not the first thing they have tried, but they have read or heard ‘you may be able to use plasma' to solve a specific problem," explains Barden. "They have a target for their material or the chemistry, but very often they don't know exactly how to get there. So, it can be somewhat experimental."

When this is the case, the initial capital costs may be a deterrent. Even large medical device manufacturers may opt to avoid purchasing equipment initially if the product is new, or a new version, and production quantities are unknown.

The other type of inquires received are from companies where outsourcing is a core concept of their corporate philosophy. This could also be true for medical device companies that want to develop the product, but only assemble and do final packaging in house, along with contract sub-assemblers.

Plasma Treatments
According to Barden, many contract processing projects involve using plasma to create a high-energy surface to resolve bonding issues with chemical adhesives.

Plasma treatments are utilized to increase the surface free energy of the material to be bonded.
When a substrate has a high surface energy, it tends to attract. For this reason, adhesives and other liquids often spread more easily across the surface. This wettability promotes superior adhesion.

Adhesion promotion can be achieved by increasing the surface free energy through several mechanisms, including precision cleaning, chemically or physically modifying the surface, increasing surface area by roughening and primer coatings.

The net effect is a tremendous improvement in bonding. In some cases, up to a 50 times bond strength improvement can be achieved.

On the other hand, substrates that have a low surface energy, such as PTFE, are difficult to adhere to other materials without first selectively altering the surface to increase the free energy.

"When a surface is really hydrophobic, like Teflon, it's very difficult to bond to it," says Barden. "If you apply a liquid or adhesive, by nature it pools and will not spread effectively across the surface."

There are several plasma methods employed to increase surface energy, including physical and chemical plasmas along with PECVD coating surfaces.

Silicon, another material widely used in the industry for its low surface energy, often it is utilized as an over-molding compound to protect electronic boards from extreme conditions.

Unfortunately, the topography of a PCB means the silicone must bond to many types of materials, including polymers, metals, alloys, ceramics and the FR-4 board itself, all of which have unique surface energies and chemistries.

Without proper adhesion, silicone can begin to delaminate, not only at the edges of the PCB board but also in the form of small air pockets on, or around, components. This can lead to moisture ingress and subsequent corrosion or electrical shorts.

"In terms of surface energy, the best strategy is to deposit a thin film coating over everything so the silicone only has to bond to one surface energy," says Barden. "A process using plasma can basically harmonize all of the many surfaces and turn it into one."

To accomplish this, PVA TePla has developed a specific process starting with a precision cleaning/surface activation treatment followed by the deposition of an inert chemical primer that serves as a tie layer for the over-molding and provides a uniform surface energy for the silicone to bond.

Gas plasma can also provide surface conditioning of in vitro diagnostic platforms prior to the adsorption of biological molecules (protein/antibody, cells, carbohydrate, etc.) or biomimetic polymers. This includes precision cleaning of the substrate at the molecular level, along with raising the surface energy to improve surface assimilation of the intended content.

"Microtiter and multiwell plates are often made of polystyrene, which is extremely hydrophobic. Water will bead on it," says Barden. "However, if you treat polystyrene with oxygen plasma it will become very hydrophilic, so liquid spreads everywhere. This allows aqueous solutions containing biological content to spread and deliver biomolecules to the surface while providing a hydrogen bonding platform to adhere them."

However, some in vitro diagnostic substrates require more selective surface chemistry to immobilize a customer's proprietary molecules. For this, PVA TePla has recently developed methods for chemically functionalizing various polymer platforms for the selective adhesion promotion and conjugation of bio-active molecules.

This is achieved by providing particular chemical functionality or linker chemistries at the surface, allowing conjugation of a wide variety of molecules ranging from small molecule drugs to peptides to larger biopolymers such as carbohydrates and antibodies. Amino, carboxylic, hydroxyl and epoxy functionalities are important examples of the chemistries that are readily obtainable using a gas plasma surface treatment.

Expertise in Plasma Treatments
Contract processors should ideally bring a combination of resources for plasma R&D and experience with many customer types in markets beyond medical devices.

Working with a contract processor also has tremendous advantages when it comes to tapping into the years of technical expertise applying a variety of plasma treatments. This can often speed research and development efforts significantly.

In many ways, the application of plasma is the domain of chemists and other scientists. Companies like PVA TePla, for example, have three Ph.D. scientists and surface, polymer, physical, bio and organic chemists, as well as engineers, plasma physicists and metallurgists on staff.

"Because we see the similarities in the types of materials being treated, our experience allows us to develop and optimize custom proprietary processes quickly and efficiently, saving our customers significant time and money in the development phase of product development" says Barden.

An extensive knowledge and experience manufacturing plasma equipment is also a plus, given that most contract processors just purchase equipment from global providers.

However, with a background in plasma equipment manufacturer, the contract processor can provide critical insight on validation, production methods, fixturing, as well as hardware and software modifications. Examples include special hardware for batch processing, such as a mass flow controller, a different pump configuration or unique chamber sizes.

Additional specifications for a process for electronic part, anti-static so when it comes out of the plasma because it's an electron emitter, it can accumulate static; Anti-static fans can be used to remove static on the parts when the chamber is opened.

"Depending on the application and complexity, customers face strict industry requirements and often have unique product of processing requirements," explains Barden. "Generally, we have existing solutions for most of the things, so usually that is not a concern.

Even the way the parts are delivered to the contract processor, or how they are packaged and returned can be modified as needed.

Parts can be sent in specific counts in bags or in specifically designed pre-loaded trays, for example. Once treated, the parts are typically packaged in polyethylene bags, but for customers with electronic devices like PCBs, antistatic bags can be specified to protect components from electrostatic discharge (ESD).

The company operates nine plasma system lines. So, what happens is usually we can run through three jobs simultaneously.

As for turnaround time, it depends on the quantity and complexity of the processing. However, it can be quite fast. A single batch can be completed in an hour, and large batches of, say, 1,500 parts can be treated and shipped within a day or two.

For medical device manufacturers interested in treating parts and components with plasma, but do not want to make the investment just yet, or require only small batches, outsourcing it to a qualified contract processor could be the solution they are seeking.

For more information, contact PVA TePla America at 951-371-2500 or 800-527-5667, rayc@pvateplaamerica.com or visit www.pvateplaamerica.com.

Featured Product

ResinDek® TRIGARD® ESD ULTRA FOR HIGH-TRAFFIC ROBOTIC APPLICATIONS

ResinDek® TRIGARD® ESD ULTRA FOR HIGH-TRAFFIC ROBOTIC APPLICATIONS

To maximize the productivity of an autonomous mobile robot (AMR) or automatic guided vehicle (AGV) deployment, it's critical to create the optimal environment that allows the vehicles to perform at their peak. For that reason, Cornerstone Specialty Wood Products, LLC® (www.resindek.com) created the TriGard® ESD Ultra finish for its ResinDek® engineered flooring panels. The TriGard ESD Ultra finish is ideal for high-traffic robotic applications characterized by highly repetitive movement patterns and defined travel paths.